Skip to main content
Dollar TreeTech adoption

A low-voltage technician reports having previously performed difficult ceiling-mounted equipment installations at Dollar Tree retail sites.

What happened

Post: "Need some help with this one!"

Source

RedditSep 22, 2026By u/702PoGoHunter

r/lowvoltage

Need some help with this one!

upvotes
41
comments
47

Extracted from these lines

  • [comment u/killiansmith19] If you get a single man lift you can usually take out some of the ceiling grid parts to get up into the ceiling high enough. We’ve done it before at Dollar Tree sites.

reddit.com/r/lowvoltage/comments/1wno52t/need_some_help_with_this_oneOpen the source

Comments on the post

5 of 47 comments
  • “That's going to be a change order. Especially since they moved locations after the survey.”

    u/senkosferda34 points · Sep 22, 2026View

  • “Escalate. Tell them the situation and that your going to have to tear out ceiling grid and then have that repaired to make it secure. Let them make the call.”

    u/gnjoey27 points · Sep 22, 2026View

  • “Try throwing some wire up and over the truss then you can tape your safety wire to it and pull it through. Or any sort of weight onto pull string works too. You’ll have to wrap the safety wire pretty low instead of up by the truss like is proper, but it still holds.”

    u/BuffaloDV15 points · Sep 22, 2026View

  • “LOL, I just posted this in r/electricians about homemade tools We made a tool for hanging suspended ceiling wire from bar joists for 2x4’s out of 3/4 EMT. You cut along the EMT on an angle making a spiral cut and then flattened it out like a flag, but leave a hook at the end. Then you bend 2 slight, close offsets so you can spin it easily. You then take 1/2 a dozen or so ceiling wires, bend th”

    u/Switchedbywife11 points · Sep 22, 2026View

  • “Sound like you already have the plan for the tile mount. Can do the suspension with stranded cable or grid wire. Grid wire is easy if the iron isn't much more than 10' up. What you want to do is take a piece of EMT conduit and partially cut through it at an angle and "unpeel" it in a spiral with some pliers until it has a flag of material several inches long perpendicular to the length. Then you”

    u/grivooga4 points · Sep 22, 2026View

Extracted by Autobound

From the Signal API record
Signal
Tech adoption

What this signalsUser posts often show product pain before it reaches reviews or churn.

Subreddit
r/lowvoltage
Stage
Switched

The full record

From the Signal API record

Numbers

Mentions
1

Details

Timing
Completed
Category
low-voltage infrastructure
Link URL
i.redd.it
Virality
High
Post kind
Image
Prominence
Aside
Company's role
Buyer

Topics and mentions

Topics

  • installation
  • low-voltage
  • facilities
  • retail

Extraction

Sentiment
Neutral
Detected
Sep 22, 2026
signal_type
reddit-company
signal_subtype
techAdoption

Use this data

Get every Reddit signal for Dollar Tree and the companies you sell to, in the tools you already use.

  1. Ask Claude about it

    Connect Autobound to Claude, Claude Code or Cursor with MCP. Then ask: “What changed at Dollar Tree this week?”

  2. Send it to your own tools

    The Signal API returns Reddit signals for any list of companies as JSON, for your CRM, warehouse or app.

  3. Try it free

    Sign up and spend your free credits on the companies you sell to.

    Start Free1,000 free credits

The API returns more than this page shows

This page shows a preview. The full reddit-company record in the Signal API and MCP can also have these 8 fields. Some fields are empty for some signals.

Company

  • linkedin_urlValue in the API
  • industriesValue in the API
  • employee_count_lowValue in the API
  • employee_count_highValue in the API
  • revenueValue in the API
  • descriptionValue in the API

Signal

  • signal_nameValue in the API
  • associationValue in the API
Show the full JSONThe record on this page and the API request

GET /v1/signals/cb2e56de-599a-5f1d-add6-abd8425094f7 returns this record as JSON. POST /v1/companies/enrich returns every signal for dollartree.com.

{
  "signal_id": "cb2e56de-599a-5f1d-add6-abd8425094f7",
  "signal_type": "reddit-company",
  "signal_subtype": "techAdoption",
  "detected_at": "2026-09-22T22:30:15+00:00",
  "company": {
    "name": "Dollar Tree",
    "domain": "dollartree.com"
  },
  "data": {
    "nsfw": false,
    "stage": "switched",
    "awards": 0,
    "timing": "completed",
    "topics": [
      "installation",
      "retail",
      "low-voltage",
      "facilities"
    ],
    "post_id": "1wno52t",
    "summary": "A low-voltage technician reports having previously performed difficult ceiling-mounted equipment installations at Dollar Tree retail sites.",
    "category": "low-voltage infrastructure",
    "comments": [
      {
        "url": "https://www.reddit.com/r/lowvoltage/comments/1wno52t/comment/pbgkvrf/",
        "depth": 0,
        "score": 34,
        "author": "senkosferda",
        "excerpt": "That's going to be a change order. Especially since they moved locations after the survey.",
        "posted_at": "2026-09-22T22:51:20.000Z",
        "author_url": "https://www.reddit.com/user/senkosferda/"
      },
      {
        "url": "https://www.reddit.com/r/lowvoltage/comments/1wno52t/comment/pbgkhp3/",
        "depth": 0,
        "score": 27,
        "author": "gnjoey",
        "excerpt": "Escalate. Tell them the situation and that your going to have to tear out ceiling grid and then have that repaired to make it secure. Let them make the call.",
        "posted_at": "2026-09-22T22:49:16.000Z",
        "author_url": "https://www.reddit.com/user/gnjoey/"
      },
      {
        "url": "https://www.reddit.com/r/lowvoltage/comments/1wno52t/comment/pbgktxj/",
        "depth": 0,
        "score": 15,
        "author": "BuffaloDV",
        "excerpt": "Try throwing some wire up and over the truss then you can tape your safety wire to it and pull it through. Or any sort of weight onto pull string works too. You’ll have to wrap the safety wire pretty low instead of up by the truss like is proper, but it still holds.",
        "posted_at": "2026-09-22T22:51:04.000Z",
        "author_url": "https://www.reddit.com/user/BuffaloDV/"
      },
      {
        "url": "https://www.reddit.com/r/lowvoltage/comments/1wno52t/comment/pbgq6qe/",
        "depth": 0,
        "score": 11,
        "author": "Switchedbywife",
        "excerpt": "LOL, I just posted this in r/electricians about homemade tools\n\n We made a tool for hanging suspended ceiling wire from bar joists for 2x4’s out of 3/4 EMT. You cut along the EMT on an angle making a spiral cut and then flattened it out like a flag, but leave a hook at the end. Then you bend 2 slight, close offsets so you can spin it easily.\n\n You then take 1/2 a dozen or so ceiling wires, bend th",
        "posted_at": "2026-09-22T23:20:07.000Z",
        "author_url": "https://www.reddit.com/user/Switchedbywife/"
      },
      {
        "url": "https://www.reddit.com/r/lowvoltage/comments/1wno52t/comment/pbgqjl1/",
        "depth": 0,
        "score": 4,
        "author": "grivooga",
        "excerpt": "Sound like you already have the plan for the tile mount. Can do the suspension with stranded cable or grid wire.\n\n Grid wire is easy if the iron isn't much more than 10' up. What you want to do is take a piece of EMT conduit and partially cut through it at an angle and \"unpeel\" it in a spiral with some pliers until it has a flag of material several inches long perpendicular to the length. Then you",
        "posted_at": "2026-09-22T23:22:05.000Z",
        "author_url": "https://www.reddit.com/user/grivooga/"
      },
      {
        "url": "https://www.reddit.com/r/lowvoltage/comments/1wno52t/comment/pbgtff5/",
        "depth": 0,
        "score": 4,
        "author": "Foreign-Plate9483",
        "excerpt": "Stand on the top rails 🤪. If you’ve ever done fire alarm and found a different way to get to duct detectors god bless yah.",
        "posted_at": "2026-09-22T23:37:57.000Z",
        "author_url": "https://www.reddit.com/user/Foreign-Plate9483/"
      },
      {
        "url": "https://www.reddit.com/r/lowvoltage/comments/1wno52t/comment/pbgxsy6/",
        "depth": 0,
        "score": 4,
        "author": "Canadian-electrician",
        "excerpt": "Sammy x-press with a pole extension on the driver. Hang 3/8 rod from it",
        "posted_at": "2026-09-23T00:01:51.000Z",
        "author_url": "https://www.reddit.com/user/Canadian-electrician/"
      },
      {
        "url": "https://www.reddit.com/r/lowvoltage/comments/1wno52t/comment/pbh2ldl/",
        "depth": 0,
        "score": 4,
        "author": "Derrek__",
        "excerpt": "Tape and some string, throw it over the iron and you're good. Don't forget the safety chain for the pvm. If this is for Ross, good luck!",
        "posted_at": "2026-09-23T00:27:37.000Z",
        "author_url": "https://www.reddit.com/user/Derrek__/"
      }
    ],
    "evidence": [
      "[comment u/killiansmith19] If you get a single man lift you can usually take out some of the ceiling grid parts to get up into the ceiling high enough. We’ve done it before at Dollar Tree sites."
    ],
    "link_url": "https://i.redd.it/6x8o5ntke5rh1.jpeg",
    "virality": "high",
    "image_url": "https://i.redd.it/6x8o5ntke5rh1.jpeg",
    "post_date": "2026-09-22T22:30:15.000Z",
    "post_kind": "image",
    "sentiment": "neutral",
    "subreddit": "lowvoltage",
    "post_title": "Need some help with this one!",
    "prominence": "aside",
    "source_url": "https://www.reddit.com/r/lowvoltage/comments/1wno52t/need_some_help_with_this_one/",
    "entity_role": "buyer",
    "post_author": "702PoGoHunter",
    "upvote_ratio": 0.9767441860465116,
    "mention_count": 1,
    "mention_surge": false,
    "subreddit_url": "https://www.reddit.com/r/lowvoltage/",
    "total_upvotes": 41,
    "comments_total": 47,
    "total_comments": 47,
    "event_date_text": "before",
    "post_author_url": "https://www.reddit.com/user/702PoGoHunter/",
    "signal_category": "adoption",
    "comments_included": 13
  }
}

Long text fields are shortened on this page.

Looking up one signal by its id is free. Enrich costs 2 credits per signal returned; a call with no results is free.