A technician working with a Bosch B9512G panel reports trouble wiring it up, noting that every newly installed point registers as a short despite using a setup that worked on previous Bosch POPIT...

What happened

A technician working with a Bosch B9512G panel reports trouble wiring it up, noting that every newly installed point registers as a short despite using a setup that worked on previous Bosch POPIT installations.

Source

RedditOct 8, 2026By u/Ok_Contest2893

r/firealarms

How would yall Wire this

upvotes
12
comments
22

Extracted from these lines

  • [comment u/Ok_Contest2893] Working with a bosch b9512g panel and this isn't working I've wired it the same way on other bosch panels with POPITS never had an issue but today on the panel it says there's a short on every new one we installed and wired th

reddit.com/r/firealarms/comments/1x0j5ux/how_would_yall_wire_thisOpen the source

Comments on the post

5 of 22 comments
  • “Rtfm”

    u/loafglenn23 points · Oct 8, 2026View

  • “It's pretty straight forward. Green and red are 24VDC power. Red and black is your IDC from the zone or module. Then the black jumper connects the closed trouble relay to the alarm size before it goes through the resistor. So a trouble on the detector will open the circuit and show a trouble on the panel. Look up the wiring diagram for the 4120 and it's done the same way.”

    u/horseheadmonster5 points · Oct 8, 2026View

  • “Where they're meant to go”

    u/EvilMonkey85212 points · Oct 8, 2026View

  • “Power (presumably 24vdc) connected to + and - terminals respectfully. Zone ckt or monitor ckt connect to alarm terminals with one leg passing through the trouble contacts. Install resistor on alarm terminals. It’s always best to understand the system that you are working on. That way you can apply that to any situation, instead of relying on specific instructions for any given scenario. Best of lu”

    u/realrockandrolla1 points · Oct 8, 2026View

  • “Yea basically resistor lands on normally open on alarm and Sup and jumper from common to common on alarm and Sup. Then your wires from the module land on the alarm contacts. Working with a bosch b9512g panel and this isn't working I've wired it the same way on other bosch panels with POPITS never had an issue but today on the panel it says there's a short on every new one we installed and wired th”

    u/Ok_Contest28930 points · Oct 8, 2026View

Extracted by Autobound

From the Signal API record
Signal
Customer feedback

What this signalsUser posts often show product pain before it reaches reviews or churn.

Subreddit
r/firealarms
Event date
Oct 2026

The full record

From the Signal API record

Numbers

Mentions
1

Details

Timing
In progress
Category
Implementation
Link URL
reddit.com
Virality
Somewhat high
Post kind
Gallery
Prominence
Core
Company's role
Vendor

Topics and mentions

Topics

  • fire alarm
  • hardware wiring
  • troubleshooting
  • implementation

Flair

  • Technical Support:snoo sad:

Products named

  • B9512G
  • POPITS

Extraction

Sentiment
Negative
Detected
Oct 8, 2026
signal_type
reddit-company
signal_subtype
customerFeedback

Use this data

Get every Reddit signal for Bosch and the companies you sell to, in the tools you already use.

  1. Ask Claude about it

    Connect Autobound to Claude, Claude Code or Cursor with MCP. Then ask: “What changed at Bosch this week?”

  2. Send it to your own tools

    The Signal API returns Reddit signals for any list of companies as JSON, for your CRM, warehouse or app.

  3. Try it free

    Sign up and spend your free credits on the companies you sell to.

    Start Free1,000 free credits

The API returns more than this page shows

This page shows a preview. The full reddit-company record in the Signal API and MCP can also have these 8 fields. Some fields are empty for some signals.

Company

  • linkedin_urlValue in the API
  • industriesValue in the API
  • employee_count_lowValue in the API
  • employee_count_highValue in the API
  • revenueValue in the API
  • descriptionValue in the API

Signal

  • signal_nameValue in the API
  • associationValue in the API
Show the full JSONThe record on this page and the API request

GET /v1/signals/09bd1e56-791f-5bcf-a936-2beffadde94f returns this record as JSON. POST /v1/companies/enrich returns every signal for bosch.com.

{
  "signal_id": "09bd1e56-791f-5bcf-a936-2beffadde94f",
  "signal_type": "reddit-company",
  "signal_subtype": "customerFeedback",
  "detected_at": "2026-10-08T05:57:15+00:00",
  "company": {
    "name": "Bosch",
    "domain": "bosch.com"
  },
  "data": {
    "nsfw": false,
    "stage": "none",
    "awards": 0,
    "timing": "in_progress",
    "topics": [
      "fire alarm",
      "hardware wiring",
      "troubleshooting",
      "implementation"
    ],
    "post_id": "1x0j5ux",
    "summary": "A technician working with a Bosch B9512G panel reports trouble wiring it up, noting that every newly installed point registers as a short despite using a setup that worked on previous Bosch POPIT installations.",
    "category": "implementation",
    "comments": [
      {
        "url": "https://www.reddit.com/r/firealarms/comments/1x0j5ux/comment/pel36xr/",
        "depth": 0,
        "score": 23,
        "author": "loafglenn",
        "excerpt": "Rtfm",
        "posted_at": "2026-10-08T06:07:08.000Z",
        "author_url": "https://www.reddit.com/user/loafglenn/"
      },
      {
        "url": "https://www.reddit.com/r/firealarms/comments/1x0j5ux/comment/pel6lua/",
        "depth": 0,
        "score": 5,
        "author": "horseheadmonster",
        "excerpt": "It's pretty straight forward. Green and red are 24VDC power. Red and black is your IDC from the zone or module. Then the black jumper connects the closed trouble relay to the alarm size before it goes through the resistor. So a trouble on the detector will open the circuit and show a trouble on the panel. Look up the wiring diagram for the 4120 and it's done the same way.",
        "posted_at": "2026-10-08T06:33:56.000Z",
        "author_url": "https://www.reddit.com/user/horseheadmonster/"
      },
      {
        "url": "https://www.reddit.com/r/firealarms/comments/1x0j5ux/comment/pen9kfe/",
        "depth": 0,
        "score": 2,
        "author": "EvilMonkey8521",
        "excerpt": "Where they're meant to go",
        "posted_at": "2026-10-08T14:31:43.000Z",
        "author_url": "https://www.reddit.com/user/EvilMonkey8521/"
      },
      {
        "url": "https://www.reddit.com/r/firealarms/comments/1x0j5ux/comment/pemqjae/",
        "depth": 0,
        "score": 1,
        "author": "realrockandrolla",
        "excerpt": "Power (presumably 24vdc) connected to + and - terminals respectfully. Zone ckt or monitor ckt connect to alarm terminals with one leg passing through the trouble contacts. Install resistor on alarm terminals. It’s always best to understand the system that you are working on. That way you can apply that to any situation, instead of relying on specific instructions for any given scenario. Best of lu",
        "posted_at": "2026-10-08T13:06:00.000Z",
        "author_url": "https://www.reddit.com/user/realrockandrolla/"
      },
      {
        "url": "https://www.reddit.com/r/firealarms/comments/1x0j5ux/comment/pelpvk2/",
        "depth": 0,
        "score": 0,
        "author": "Ok_Contest2893",
        "excerpt": "Yea basically resistor lands on normally open on alarm and Sup and jumper from common to common on alarm and Sup. Then your wires from the module land on the alarm contacts. Working with a bosch b9512g panel and this isn't working I've wired it the same way on other bosch panels with POPITS never had an issue but today on the panel it says there's a short on every new one we installed and wired th",
        "posted_at": "2026-10-08T09:12:55.000Z",
        "author_url": "https://www.reddit.com/user/Ok_Contest2893/"
      }
    ],
    "evidence": [
      "[comment u/Ok_Contest2893] Working with a bosch b9512g panel and this isn't working I've wired it the same way on other bosch panels with POPITS never had an issue but today on the panel it says there's a short on every new one we installed and wired th"
    ],
    "link_url": "https://www.reddit.com/gallery/1x0j5ux",
    "virality": "somewhat_high",
    "post_date": "2026-10-08T05:57:15.000Z",
    "post_kind": "gallery",
    "sentiment": "negative",
    "subreddit": "firealarms",
    "event_date": "2026-10",
    "post_flair": [
      "Technical Support:snoo_sad:"
    ],
    "post_title": "How would yall Wire this",
    "prominence": "core",
    "source_url": "https://www.reddit.com/r/firealarms/comments/1x0j5ux/how_would_yall_wire_this/",
    "entity_role": "vendor",
    "post_author": "Ok_Contest2893",
    "upvote_ratio": 0.7727272727272727,
    "mention_count": 1,
    "mention_surge": false,
    "subreddit_url": "https://www.reddit.com/r/firealarms/",
    "total_upvotes": 12,
    "comments_total": 22,
    "total_comments": 22,
    "event_date_text": "today",
    "post_author_url": "https://www.reddit.com/user/Ok_Contest2893/",
    "signal_category": "feedback",
    "comments_included": 5,
    "products_mentioned": [
      "B9512G",
      "POPITS"
    ]
  }
}

Long text fields are shortened on this page.

Looking up one signal by its id is free. Enrich costs 2 credits per signal returned; a call with no results is free.