A commenter recommends Eaton UPSs as a 'nicer' but more expensive alternative to APC for SCADA applications, noting they support network monitoring via SNMP.

What happened

Post: "UPS connected to scada system."

Source

RedditSep 15, 2026By u/2017_JKU

r/SCADA

UPS connected to scada system.

upvotes
3
comments
17

Post

Looking for a low cost solution for a ups that can connect via Ethernet to a scada network. It will only need to power an rtu and a couple of switches for ~5 minutes. Actual time will be less than that but a few minutes is more than enough so the generator can start. It will talk to VTscada and report things like status,Runtime, and voltage. Thanks

Extracted from these lines

  • [comment u/CoiledSpringTension] Less cheap and works but a bit nicer? Eaton

  • [comment u/CoiledSpringTension] Both you can read into scada over the network via SNMP.

reddit.com/r/SCADA/comments/1whdbx2/ups_connected_to_scada_systemRead the full source

Comments on the post

5 of 17 comments
  • “We are almost exclusively APC UPSs, older installs use the Dry Contact card landing on the main cabinet PLC which alarm through the usual routes, newer installs use NMC2/3 network cards which alarm via the PRTG UA server (which reads the card info via the APC UPS Health sensor) into the main Alarm screen”

    u/iwillbewaiting2460112 points · Sep 17, 2026View

  • “Cheap and works? APC with network management card Less cheap and works but a bit nicer? Eaton Both you can read into scada over the network via SNMP. For the exact model it will depend on what voltage etc you are supplying and need to run at. Assuming I’m understanding the request right”

    u/CoiledSpringTension10 points · Sep 15, 2026View

  • “I always size my UPS to run for two hours. It's not the generator kick in time that matters, it's the time it takes someone to fix the generator.”

    u/Buenodiablo5 points · Sep 16, 2026View

  • “For 120 V equipment in an indoor rack, I’d price a CyberPower OR500LCDRM1U with the RMCARD205. The UPS is rated 500 VA / 300 W and gives a stated 12 minutes at half load, but only 3 minutes at full load. The card is what puts it on Ethernet with SNMP; budget for both. CyberPower’s listed MSRPs add up to about $679. VTScada has an SNMP driver, so you can poll the UPS for on-battery status, estima”

    u/CharlesHNetEng1 points · Sep 16, 2026View

  • “Apc”

    u/jr_jr121 points · Sep 15, 2026View

Extracted by Autobound

From the Signal API record
Signal
Customer feedback

What this signalsUser posts often show product pain before it reaches reviews or churn.

Subreddit
r/SCADA

Companies

  • APC by Schneider ElectricAlso named

The full record

From the Signal API record

Numbers

Mentions
2

Details

Category
General
Virality
Medium
Post kind
Text
Prominence
Aside
Company's role
Vendor

Topics and mentions

Topics

  • integration
  • ups
  • scada
  • snmp

Flair

  • Question

Extraction

Sentiment
Positive
Detected
Sep 15, 2026
signal_type
reddit-company
signal_subtype
customerFeedback

Use this data

Get every Reddit signal for Eaton and the companies you sell to, in the tools you already use.

  1. Ask Claude about it

    Connect Autobound to Claude, Claude Code or Cursor with MCP. Then ask: “What changed at Eaton this week?”

  2. Send it to your own tools

    The Signal API returns Reddit signals for any list of companies as JSON, for your CRM, warehouse or app.

  3. Try it free

    Sign up and spend your free credits on the companies you sell to.

    Start Free1,000 free credits

The API returns more than this page shows

This page shows a preview. The full reddit-company record in the Signal API and MCP can also have these 8 fields. Some fields are empty for some signals.

Company

  • linkedin_urlValue in the API
  • industriesValue in the API
  • employee_count_lowValue in the API
  • employee_count_highValue in the API
  • revenueValue in the API
  • descriptionValue in the API

Signal

  • signal_nameValue in the API
  • associationValue in the API
Show the full JSONThe record on this page and the API request

GET /v1/signals/23dd0735-eb8b-5853-ae70-214de8907db6 returns this record as JSON. POST /v1/companies/enrich returns every signal for eaton.com.

{
  "signal_id": "23dd0735-eb8b-5853-ae70-214de8907db6",
  "signal_type": "reddit-company",
  "signal_subtype": "customerFeedback",
  "detected_at": "2026-09-15T21:22:01+00:00",
  "company": {
    "name": "Eaton",
    "domain": "eaton.com"
  },
  "data": {
    "nsfw": false,
    "stage": "none",
    "awards": 0,
    "topics": [
      "ups",
      "scada",
      "integration",
      "snmp"
    ],
    "post_id": "1whdbx2",
    "summary": "A commenter recommends Eaton UPSs as a 'nicer' but more expensive alternative to APC for SCADA applications, noting they support network monitoring via SNMP.",
    "category": "general",
    "comments": [
      {
        "url": "https://www.reddit.com/r/SCADA/comments/1whdbx2/comment/pa9z5ch/",
        "depth": 0,
        "score": 12,
        "author": "iwillbewaiting24601",
        "excerpt": "We are almost exclusively APC UPSs, older installs use the Dry Contact card landing on the main cabinet PLC which alarm through the usual routes, newer installs use NMC2/3 network cards which alarm via the PRTG UA server (which reads the card info via the APC UPS Health sensor) into the main Alarm screen",
        "posted_at": "2026-09-17T00:42:16.000Z",
        "author_url": "https://www.reddit.com/user/iwillbewaiting24601/"
      },
      {
        "url": "https://www.reddit.com/r/SCADA/comments/1whdbx2/comment/pa1i4l3/",
        "depth": 0,
        "score": 10,
        "author": "CoiledSpringTension",
        "excerpt": "Cheap and works? APC with network management card\nLess cheap and works but a bit nicer? Eaton\n\n Both you can read into scada over the network via SNMP.\n\n For the exact model it will depend on what voltage etc you are supplying and need to run at.\n\n Assuming I’m understanding the request right",
        "posted_at": "2026-09-15T21:28:14.000Z",
        "author_url": "https://www.reddit.com/user/CoiledSpringTension/"
      },
      {
        "url": "https://www.reddit.com/r/SCADA/comments/1whdbx2/comment/pa2xxnp/",
        "depth": 0,
        "score": 5,
        "author": "Buenodiablo",
        "excerpt": "I always size my UPS to run for two hours. It's not the generator kick in time that matters, it's the time it takes someone to fix the generator.",
        "posted_at": "2026-09-16T01:57:04.000Z",
        "author_url": "https://www.reddit.com/user/Buenodiablo/"
      },
      {
        "url": "https://www.reddit.com/r/SCADA/comments/1whdbx2/comment/pa96gd2/",
        "depth": 0,
        "score": 1,
        "author": "CharlesHNetEng",
        "excerpt": "For 120 V equipment in an indoor rack, I’d price a CyberPower OR500LCDRM1U with the RMCARD205. The UPS is rated 500 VA / 300 W and gives a stated 12 minutes at half load, but only 3 minutes at full load. The card is what puts it on Ethernet with SNMP; budget for both. CyberPower’s listed MSRPs add up to about $679.\n\n VTScada has an SNMP driver, so you can poll the UPS for on-battery status, estima",
        "posted_at": "2026-09-16T22:11:35.000Z",
        "author_url": "https://www.reddit.com/user/CharlesHNetEng/"
      },
      {
        "url": "https://www.reddit.com/r/SCADA/comments/1whdbx2/comment/pa1o2yt/",
        "depth": 0,
        "score": 1,
        "author": "jr_jr12",
        "excerpt": "Apc",
        "posted_at": "2026-09-15T21:56:05.000Z",
        "author_url": "https://www.reddit.com/user/jr_jr12/"
      },
      {
        "url": "https://www.reddit.com/r/SCADA/comments/1whdbx2/comment/pa1qbrk/",
        "depth": 0,
        "score": 1,
        "author": "Robbudge",
        "excerpt": "We use a mix of tradition desktop UPS or Din rail DC ups for others.",
        "posted_at": "2026-09-15T22:07:03.000Z",
        "author_url": "https://www.reddit.com/user/Robbudge/"
      },
      {
        "url": "https://www.reddit.com/r/SCADA/comments/1whdbx2/comment/pa24gfn/",
        "depth": 0,
        "score": 1,
        "author": "Different-Moment-386",
        "excerpt": "We use vertiv ups",
        "posted_at": "2026-09-15T23:19:47.000Z",
        "author_url": "https://www.reddit.com/user/Different-Moment-386/"
      },
      {
        "url": "https://www.reddit.com/r/SCADA/comments/1whdbx2/comment/pa2avm8/",
        "depth": 0,
        "score": 1,
        "author": "enraged768",
        "excerpt": "Our waste water plant uses schnieder who own APC. Ours are big bastards that can run a cabinet with all the network equipment and plcs for a few hours. Even though we have redundant catapillar 3516 Gen sets. Because shit happens.",
        "posted_at": "2026-09-15T23:54:01.000Z",
        "author_url": "https://www.reddit.com/user/enraged768/"
      }
    ],
    "evidence": [
      "[comment u/CoiledSpringTension] Less cheap and works but a bit nicer? Eaton",
      "[comment u/CoiledSpringTension] Both you can read into scada over the network via SNMP."
    ],
    "virality": "medium",
    "post_date": "2026-09-15T21:22:01.000Z",
    "post_kind": "text",
    "post_text": "Looking for a low cost solution for a ups that can connect via Ethernet to a scada network. It will only need to power an rtu and a couple of switches for ~5 minutes. Actual time will be less than that but a few minutes is more than enough so the generator can start.\n\nIt will talk to VTscada and report things like status,Runtime, and voltage.\n\nThanks",
    "sentiment": "positive",
    "subreddit": "SCADA",
    "post_flair": [
      "Question"
    ],
    "post_title": "UPS connected to scada system.",
    "prominence": "aside",
    "source_url": "https://www.reddit.com/r/SCADA/comments/1whdbx2/ups_connected_to_scada_system/",
    "entity_role": "vendor",
    "post_author": "2017_JKU",
    "upvote_ratio": 1,
    "mention_count": 2,
    "mention_surge": false,
    "subreddit_url": "https://www.reddit.com/r/SCADA/",
    "total_upvotes": 3,
    "comments_total": 17,
    "total_comments": 17,
    "other_companies": [
      {
        "name": "APC by Schneider Electric",
        "role": "competitor",
        "domain": "se.com"
      }
    ],
    "post_author_url": "https://www.reddit.com/user/2017_JKU/",
    "signal_category": "feedback",
    "comments_included": 10
  }
}

Long text fields are shortened on this page.

Looking up one signal by its id is free. Enrich costs 2 credits per signal returned; a call with no results is free.