r/PoolPros
Pentair MT 400. Ok to run heater without manifold bypass valve installed?
- upvotes
- 1
- comments
- 7
Post
Highlighted: the lines this signal was extracted from
The valve separated from the module. Found it in the thermal regulator cavity. Can I run unit tonight for an hour without it?
Also quoted as evidence
[comment u/Financial-Regret-120] Well I tried to run it. Heater fired up but was still making the rattling sound and burner shut down after about 30 seconds like before. I already replaced the thermostat and spring. Ordered new manifold bypass valve.