A user of a Waters Synapt G2-Si mass spectrometer is experiencing a regularly pulsing and unstable electrospray signal, where the signal repeatedly drops out and returns during acquisition.

What happened

Post: "Regular Pulsing and Unstable Electrospray Signal on Waters Synapt G2-Si - Any Ideas?"

Source

RedditSep 18, 2026By u/Dul_1997

r/massspectrometry

Regular Pulsing and Unstable Electrospray Signal on Waters Synapt G2-Si - Any Ideas?

upvotes
2
comments
12

Post

Highlighted: the lines this signal was extracted from

Hi everyone,I’m experiencing a pulsing and unstable electrospray signal on a Waters Synapt G2-Si. The signal initially appears normally, but after some time it completely drops out. It then comes back, runs for a while, and drops out again.Interestingly, the periods with no signal seem to last approximately the same amount of time throughout the acquisition, so the pulsing appears fairly regular.Has anyone experienced a similar issue on a Synapt G2-Si? What could cause this, and what settings or hardware components should I check?Any suggestions would be greatly appreciated. Thank you!

reddit.com/r/massspectrometry/comments/1wjbqvj/regular_pulsing_and_un...Read the full source

Comments on the post

3 of 12 comments
  • “How does the spray look? It sounds like you have a blocked capillary or something could be going on with the nebulizer gas supply etc. You can set the reference spray going and monitor it in masslynx over a long period of time to isolate the analytical probe and then repeat with a flow from the analytical sprayer to see if it is the same. When you say the signal drops out is it to zero or is t”

    u/viomoo4 points · Sep 18, 2026View

  • “I had a similar problem, the culprit was a partially clogged fret right at the connection with the source. After sonication it went away.”

    u/orangepotatocatgeek2 points · Sep 18, 2026View

  • “Does the time between signal drops change if you change the sample flow rate? If yes think HPLC/fluidics issue if no then mass spec hardware issue. Are you running a lockmass? Infuse the lock mass for 5 mins. Does it look the same? Or run anything through the reference capillary. That’ll help you narrow it down at least.”

    u/Megalomania1921 points · Sep 18, 2026View

Extracted by Autobound

From the Signal API record
Signal
Customer feedback

What this signalsUser posts often show product pain before it reaches reviews or churn.

Subreddit
r/massspectrometry
Event date
Sep 2026

The full record

From the Signal API record

Numbers

Mentions
1

Details

Timing
In progress
Category
Reliability
Virality
Low
Post kind
Text
Prominence
Core
Company's role
Vendor

Topics and mentions

Topics

  • mass spectrometry
  • technical support
  • hardware issue
  • reliability

Products named

  • Synapt G2-Si
  • MassLynx

Extraction

Sentiment
Negative
Detected
Sep 18, 2026
signal_type
reddit-company
signal_subtype
customerFeedback

Use this data

Get every Reddit signal for Waters and the companies you sell to, in the tools you already use.

  1. Ask Claude about it

    Connect Autobound to Claude, Claude Code or Cursor with MCP. Then ask: “What changed at Waters this week?”

  2. Send it to your own tools

    The Signal API returns Reddit signals for any list of companies as JSON, for your CRM, warehouse or app.

  3. Try it free

    Sign up and spend your free credits on the companies you sell to.

    Start Free1,000 free credits

The API returns more than this page shows

This page shows a preview. The full reddit-company record in the Signal API and MCP can also have these 8 fields. Some fields are empty for some signals.

Company

  • linkedin_urlValue in the API
  • industriesValue in the API
  • employee_count_lowValue in the API
  • employee_count_highValue in the API
  • revenueValue in the API
  • descriptionValue in the API

Signal

  • signal_nameValue in the API
  • associationValue in the API
Show the full JSONThe record on this page and the API request

GET /v1/signals/1ba48de0-93e1-5043-af45-67d15f2d2ab9 returns this record as JSON. POST /v1/companies/enrich returns every signal for waters.com.

{
  "signal_id": "1ba48de0-93e1-5043-af45-67d15f2d2ab9",
  "signal_type": "reddit-company",
  "signal_subtype": "customerFeedback",
  "detected_at": "2026-09-18T00:54:25+00:00",
  "company": {
    "name": "Waters",
    "domain": "waters.com"
  },
  "data": {
    "nsfw": false,
    "stage": "none",
    "awards": 0,
    "timing": "in_progress",
    "topics": [
      "mass spectrometry",
      "technical support",
      "hardware issue",
      "reliability"
    ],
    "post_id": "1wjbqvj",
    "summary": "A user of a Waters Synapt G2-Si mass spectrometer is experiencing a regularly pulsing and unstable electrospray signal, where the signal repeatedly drops out and returns during acquisition.",
    "category": "reliability",
    "comments": [
      {
        "url": "https://www.reddit.com/r/massspectrometry/comments/1wjbqvj/comment/pahemzw/",
        "depth": 0,
        "score": 4,
        "author": "viomoo",
        "excerpt": "How does the spray look? It sounds like you have a blocked capillary or something could be going on with the nebulizer gas supply etc.\n\n You can set the reference spray going and monitor it in masslynx over a long period of time to isolate the analytical probe and then repeat with a flow from the analytical sprayer to see if it is the same.\n\n When you say the signal drops out is it to zero or is t",
        "posted_at": "2026-09-18T01:03:13.000Z",
        "author_url": "https://www.reddit.com/user/viomoo/"
      },
      {
        "url": "https://www.reddit.com/r/massspectrometry/comments/1wjbqvj/comment/paijsb2/",
        "depth": 0,
        "score": 2,
        "author": "orangepotatocatgeek",
        "excerpt": "I had a similar problem, the culprit was a partially clogged fret right at the connection with the source. After sonication it went away.",
        "posted_at": "2026-09-18T05:08:30.000Z",
        "author_url": "https://www.reddit.com/user/orangepotatocatgeek/"
      },
      {
        "url": "https://www.reddit.com/r/massspectrometry/comments/1wjbqvj/comment/paiuzaw/",
        "depth": 0,
        "score": 1,
        "author": "Megalomania192",
        "excerpt": "Does the time between signal drops change if you change the sample flow rate? If yes think HPLC/fluidics issue if no then mass spec hardware issue.\n\n Are you running a lockmass? Infuse the lock mass for 5 mins. Does it look the same? Or run anything through the reference capillary.\n\n That’ll help you narrow it down at least.",
        "posted_at": "2026-09-18T06:36:34.000Z",
        "author_url": "https://www.reddit.com/user/Megalomania192/"
      }
    ],
    "evidence": [
      "[post] Regular Pulsing and Unstable Electrospray Signal on Waters Synapt G2-Si - Any Ideas?",
      "[post] I’m experiencing a pulsing and unstable electrospray signal on a Waters Synapt G2-Si. The signal initially appears normally, but after some time it completely drops out. It then comes back, runs for a while, and drops out again.",
      "[post] Interestingly, the periods with no signal seem to last approximately the same amount of time throughout the acquisition, so the pulsing appears fairly regular."
    ],
    "virality": "low",
    "post_date": "2026-09-18T00:54:25.000Z",
    "post_kind": "text",
    "post_text": "Hi everyone,I’m experiencing a pulsing and unstable electrospray signal on a Waters Synapt G2-Si. The signal initially appears normally, but after some time it completely drops out. It then comes back, runs for a while, and drops out again.Interestingly, the periods with no signal seem to last approximately the same amount of time throughout the acquisition, so the pulsing appears fairly regular.Has anyone experienced a similar issue on a Synapt G2-Si? What could cause this, and what settings or hardware components should I check?Any suggestions would be greatly appreciated. Thank you!",
    "sentiment": "negative",
    "subreddit": "massspectrometry",
    "event_date": "2026-09",
    "post_title": "Regular Pulsing and Unstable Electrospray Signal on Waters Synapt G2-Si - Any Ideas?",
    "prominence": "core",
    "source_url": "https://www.reddit.com/r/massspectrometry/comments/1wjbqvj/regular_pulsing_and_unstable_electrospray_signal/",
    "entity_role": "vendor",
    "post_author": "Dul_1997",
    "upvote_ratio": 1,
    "mention_count": 1,
    "mention_surge": false,
    "subreddit_url": "https://www.reddit.com/r/massspectrometry/",
    "total_upvotes": 2,
    "comments_total": 12,
    "total_comments": 12,
    "post_author_url": "https://www.reddit.com/user/Dul_1997/",
    "signal_category": "feedback",
    "comments_included": 3,
    "products_mentioned": [
      "Synapt G2-Si",
      "MassLynx"
    ]
  }
}

Long text fields are shortened on this page.

Looking up one signal by its id is free. Enrich costs 2 credits per signal returned; a call with no results is free.